Goldfly is an integrated supplier specializing in the research, development, production, and sales of condensers and evaporators. Our core products encompass heat exchangers, condensers, evaporator coils, ceiling coolers, and all-in-one refrigeration units, which are primarily utilized in refrigerators, chillers, vending machines, and air conditioning systems.
Professional Team
Our team comprises seasoned professionals dedicated to providing comprehensive services to customers. Leveraging our expertise, we aim to address customer challenges effectively and offer tailored solutions.
OEM/ODM Services
We offer customized OEM and ODM services, with our professional technical team delivering a wide range of solutions based on specific customer requirements.
Production Equipment
Equipped with state-of-the-art automated production facilities for heat exchangers, including automatic welding machines, automatic punching machines, detection lines, and type laboratories, we ensure high-quality manufacturing processes.
Sales Market
Apart from supplying major refrigerator manufacturers in China, our products are exported to more than 30 countries across the Americas, Europe, the Middle East, and Asia, establishing a robust global presence.
Specification of Condenser
|
Capacity (KW) |
17.5 |
|
Surface (㎡) |
35.1 |
|
Volume (dm) |
4.3 |
|
Fan Motor Air Flow |
7600 |
|
Fan Motor Power |
480 |
|
Fan Motor Current |
1.04 |
|
DB (A) |
53 |
|
Connect Pipe Inlet |
22 |
|
Connect Pipe Outlet |
16 |
|
Weight (kg) |
48 |
Types of Condenser
The condensers produced by our company mainly include the following types
01
Air cooled Condenser
Air-cooled condenser is used to cool down heat of the refrigerant to condensate the refrigerant from the gaseous state into a liquid refrigerant. Gernerally, this type of condenser uses a fin coil which is usually made of copper tube and fin that increases the surface area to allow heat away from the refrigerant in the condenser.
02
Water cooled Condenser
Water-cooled condenser uses water as a medium to cool off the refrigerant from gas status to condense into a liquid refrigerant which causes the higher temperature of water.
03
Evaporative Condenser
Evaporative condenser is used both water and air to transfer heat from the refrigerant in the gaseous state to condensate into the liquid. Principle of Evaporative Condenser is to bring out both water-cooled condenser and the cooling tower come together in the same unit.

Applications of Condenser
The various uses of Condensers are
Air conditioning systems
Refrigeration units
Power plants
Distillation processes
Automotive cooling systems
Industrial refrigeration
Chemical and petrochemical industries
Food processing and storage
HVAC systems
Geothermal heat pumps
Installation Steps of Outdoor Condenser
● Select the Installation Site – Choose a location for the condenser unit that is away from direct sunlight and ensures it adheres to local regulations regarding setback distances, noise restrictions, and aesthetic considerations. Consider factors such as airflow and accessibility.
● Prepare the Concrete Pad – Begin by excavating the installation area, which ensures it is level and free from debris. Pour a concrete pad of appropriate size and thickness, adhering to the unit’s specifications. Reinforce the pad with steel rods for added stability.
● Check Electrical Requirements – Refer to the unit’s manual to understand its electrical specifications, including voltage, phase, and current requirements. Verify that the electrical panel can accommodate the additional load and follow local electrical codes during installation.
● Install Disconnect Box – Mount an electrical disconnect box on the wall near the condenser unit that ensures it is easily accessible. The placement should comply with electrical codes, and the box should facilitate convenient power disconnect for maintenance purposes.
● Run Electrical Wiring – Use appropriately sized electrical wires to connect the disconnect box to the condenser unit. Follow local electrical codes, and if required, use a protective tube to protect the wiring. Ensure a secure and weather-resistant electrical connection.
● Mount the Condenser Unit – Carefully place the condenser on the prepared concrete pad, taking precautions not to damage refrigerant lines or electrical connections. Orient the unit according to the manufacturer’s recommendations for optimal performance.
● Level the Unit – Use a bubble level to ensure the condenser is level in both horizontal directions. Adjust the pad if necessary to achieve proper leveling, which is essential for the unit’s stability and efficiency.
● Connect Refrigerant Lines – Braze or flare the refrigerant lines, which ensure a secure and leak-free connection. Use an appropriate torque wrench to tighten flare connections to the manufacturer’s specifications, ensuring reliability and safety.
● Install Line Set Cover – Secure the line set cover to the exterior of the building, concealing and protecting the refrigerant lines. Ensure proper drainage for condensation and provide adequate insulation for the lines to maintain efficiency.
● Install Condensate Drain Line – Connect the condensate drain line from the indoor unit to a suitable drainage location. Install a trap in the line to prevent air infiltration and ensure proper drainage, preventing water damage and maintaining system efficiency.
● Connect Control Wiring – Connect low-voltage control wiring, typically using thermostat wire, between the condenser and the indoor unit. Follow color-coded standards for consistency and ensure secure connections to enable proper communication within the HVAC system.
● Secure the Unit – Utilize approved anchors or brackets to secure the condenser unit to the concrete pad and prevent movement or vibration. Stability is crucial for the long-term performance and lifespan of the unit.
● Install the Condenser Fan – Attach the condenser fan to the top of the unit according to the manufacturer’s instructions. Make sure proper spacing and alignment with the fan motor for efficient and effective operation.
● Connect the Electrical Supply – Connect the electrical wiring from the disconnect box to the outdoor condenser unit, which follows proper safety procedures. Ensure all connections are firm and safe, and verify that wires are properly routed and protected.
● Test the System – Power on the HVAC system and systematically test each component for proper operation. Check for abnormal noises, vibrations, or issues with the condenser fan. Make sure that the system responds correctly to thermostat adjustments.
● Charge Refrigerant – Follow the manufacturer’s guidelines for refrigerant charging, using a refrigerant manifold gauge to monitor pressures. Accurately charge the system to the specified levels, which ensures optimal performance and efficiency.
● Check for Leaks – Conduct a thorough leak check using a refrigerant leak detector or soap bubbles. Identify and repair any leaks promptly to prevent refrigerant loss and maintain the system’s effectiveness.

Optimal Placement
The condenser should be placed in a well-ventilated area, free from obstructions. This placement helps in efficient heat dissipation and prevents overheating. For outside units, it’s also crucial to ensure they are placed on a level surface, preferably in a shaded area, to avoid direct sunlight, which can strain the system and reduce efficiency.
Ventilation and Space
Adequate space around the condenser ensures proper airflow, enhancing its cooling performance. Avoid placing the unit in enclosed or cluttered spaces.
Customizable Options for Evaporators
Terms of space limitations for installation and maintenance on site : We can design products to have a shorter size.
Terms of performance and capacity : The calculation program is used to obtain an accurate data sheet.
Term of speed of design : There are engineers to consult and design and draft drawing immediately
Terms of use and maintenance : For example, the company can design a heat exchanger in 4 circuits, which can switch the cover to 2 circuits on each side for ease of maintenance and piping on site.
Packaging and Shipping
|
Packaging |
Plastic film wrapping, wooden box outer packaging |
|
Shipping |
We will help you to choose the best shipping way according to your detail requirements. By sea, by air, or by express, etc. |
Our Factory
Goldfly is a Heat Exchange equipment manufacture(also known as KINGYES in China) for Refrigerator, Chiller, Vending Machine and Air Conditioning with many years of experience in customization. Located in Binzhou and near Qingdao Port, make us have quick response and shipments. Our workshop covers an area of 20,000 square meters with many first-class professional equipment and technical engineers. The condensers and evaporators produced are of single-air, double-air, and triple-air models.
Our Honor





Shandong Gold Fly Heat Exchange Equipment Co., Ltd. is one of the most professional condenser manufacturers and suppliers in China, specialized in providing high quality customized service. We warmly welcome you to wholesale bulk condenser in stock here from our factory.
condenser for spas, condenser for flammable materials storage, condenser for waste treatment plants